hydrocarbon hang-up

English to German Tech/Engineering Mechanics / Mech Engineering emissions testing
My text doesn't provide much context, but here's a good definition of HC hang-up:

4. Does not read zero when sampling ambient air
If the hydrocarbons (HC) reading is above 20 ppm immediately following a zeroing and
the probe is not measuring vehicle exhaust, this is considered a Hydrocarbon Hangup
condition. This is caused by HC residues trapped somewhere in the sample system.

http://departments.weber.edu/automotive/DTS Manual.pdf

TIA!
Proposed translations (German)
4 Kohlenwasserstoffverunreinigung

Discussion

heikeb (asker) Nov 7, 2006:
Da in Fachartikeln von HC-Rückstandstests die Rede ist, scheint Rückstand hier in der Tat der gebräuchliche Ausdruck.
Trotzdem danke! ;-)
heikeb (asker) Nov 4, 2006:
Kohlenwasserstoffrückstände wäre da schon besser. Nur gibt es da sehr wenige Google-Treffer, und vielleicht gibt es noch einen anderen Ausdruck.
heikeb (asker) Nov 4, 2006:
KW-Verunreinung,-Kontaminierung etc. werden allerdings in Bezug auf Umweltverschmutzung (auch vielleicht als Oberbegriff) gebraucht, während Hang-Up ein Spezialausdruck ist. Vielleicht gibt es da eine genauere deutsche Entsprechen.

Proposed translations

2 hrs

Kohlenwasserstoffverunreinigung

hydrocarbon hang-up = hydrocarbon contamination

Example: "The minimum requirement to keep the sample stream clean is the use of a fine-enough, heated sample filter at the stack probe. Such filters typically are change filters from various sintered materials and need to be replaced quite often. While the stack probe filter is replaced frequently, the question is who cares about the hydrocarbon contamination (hang up) in the heated sample line (and sample probe)? May be someone sometimes, but in fact a heated line should be cleaned as often as the stack probe filter is changed. Such hydrocarbon hang-up easily becomes permanent over time and generates much higher THC readings than they are in the actual sample."


Example sentence:

While the stack probe filter is replaced frequently, the question is who cares about the hydrocarbon contamination (hang up) in the heated sample line (and sample probe)?