In relation to text on bilge pumps in a power station:
Pumpene skal være dykkete pumper, leveret komplett med føringer, inntakssil, koblingsfot og tilbakeslagsventil.
Proposed translations (English)
3 duckfoot bend
3 connection fitting

Discussion

eodd Oct 1, 2013:
Hi Michael,
There's no need to apologise for doubting me. I was only "medium" certain.
Duckfoot or duckfoot bend seems to be the standard term though, and "duckfoot bend connector" doesn't get any hits on Google.
Here's another definiton of the term:
http://www.mindat.org/glossary/duckfoot
Michael Ellis Oct 1, 2013:
Duckfoot bend connector Eodd, I looked at the Tsurumi reference and just thought it might be a false translation from the Japanese.
I have now found a good UK reference (https://www.drain-systems.co.uk/product/5251) which vindicates your choice. (There are several others if you google "duckfoot bend").
I apologise for doubting you, but still have a feeling that 'connector' is important, hence I would advise Carole to use "duckfoot bend connector" but to give you the points!
eodd Sep 30, 2013:
I "borrowed" the translation from here: http://www.tsurumi-library.com/library/Manuals/Manusew.pdf
Michael Ellis Sep 30, 2013:
Connection Fitting I am unhappy with Eodd's suggestion. He has certainly defined a Duckfoot Bend, but this doesn't quite cover the capability of this fitting.
I think that 'kobling' is an important word here and so we need "connector" or "connection" in the translation. I wish I could find a decent English reference and will continue to look. Meanwhile see my suggestion.

Proposed translations

16 hrs

duckfoot bend

Duckfoot bend = In a piping system, a support fitted to the bend of a vertical pipe to permit the direct load of the pipework and fittings to be transferred to the floor, foundation, or associated installations.

/www.seterm.com/uploads/26_vortex.pdf
Something went wrong...
1 day 3 hrs

connection fitting

The extractor pump will need to be removed regularly for maintenance so it needs a semi-permanent base or bracket at the bottom of the space which fills with water, to which it is connected and through which, by means of a non-return valve, it draws water out of that space. There are good illustrations in the references, but I have not been able to find a good English reference yet. This translation is safe compromise, I feel.

--------------------------------------------------
Note added at 1 day20 hrs (2013-10-01 11:30:37 GMT)
--------------------------------------------------

See discussion - 'duckfoot bend' or 'duckfoot bend connector' would be better.
Example sentence:

The pumps are to be delivered complete with hoses, piping, connection fitting, intake filters and non-return valves